Development and validation of a sensitive LC–MS-MS method to quantify psilocin in authentic oral fluid samples
Marilia Santoro Cardoso, Kelly Francisco da Cunha, Izabelly Geraldes Silva, Taís Regina Fiorentin, Eduardo G de Campos, José Luiz Costa
Journal of Analytical Toxicology August 29, 2023 DOI: 10.1093/jat/bkad064 via OpenAlex
Summary
AI-generated from the abstractPsilocin, the active compound produced when psilocybin from magic mushrooms is ingested, is unstable and oxidizes quickly, making its detection in biological samples challenging. A new method using liquid chromatography–tandem mass spectrometry was developed and validated to measure psilocin in oral fluid. The method requires only 100 microliters of sample, achieves detection limits of 0.05 ng/mL, and performs reliably with low bias and imprecision. Psilocin was stable in oral fluid at −20°C for 24 hours, at 4°C for 72 hours, and at 24°C for 24 hours, but degraded after three freeze-thaw cycles. Analysis of five authentic samples from party attendees found psilocin concentrations between 0.08 and 36.4 ng/mL, marking the first report of such measurements in oral fluid.
Study at a glance
| Characteristics | Method development and validation Peer reviewed |
|---|---|
| Sample size | 5 |
| Population | Authentic oral fluid samples from volunteers attending parties and electronic music festivals |
| Keywords | Psychedelics Drug testing Analytical chemistry Forensic science Toxicology |
| Citations | 3 |
| Key finding | A validated LC-MS/MS method quantified psilocin in oral fluid at concentrations from 0.08 to 36.4 ng/mL, with the analyte remaining stable under specific storage conditions but not after repeated freeze-thaw cycles. |
Abstract
Abstract Psilocin is an active substance and a dephosphorylated product of psilocybin formed after the ingestion of mushrooms. The low stability caused by the quick oxidation of this analyte requires sensitive methods for its determination in biological matrices. In this work, we described the development, optimization and validation of a method for the quantification of psilocin in authentic oral fluid samples by liquid chromatography–tandem mass spectrometry. Liquid–liquid extraction was performed using 100 µL of oral fluid samples collected with a Quantisal™ device and t-butyl methyl ether as the extraction solvent. The method showed acceptable performance, with limits of detection and quantification of 0.05 ng/mL, and the calibration model was achieved between 0.05 and 10 ng/mL. Bias and imprecision results were below −14.2% and 10.7%, respectively. Ionization suppression/enhancement was lower than −30.5%, and recovery was >54.5%. Dilution integrity bias was <14.4%. No endogenous and exogenous interferences were observed upon analyzing oral fluid from 10 different sources and 56 pharmaceuticals and drugs of abuse, respectively. No carryover was observed at 10 ng/mL. Psilocin was stable in oral fluid at −20°C, 4°C and 24°C up to 24, 72 and 24 h, respectively, with variations <17.7%. The analyte was not stable after three freeze/thaw cycles, with variations between −73% and −60%. This suggests the instability of psilocin in oral fluid samples, which requires timely analysis, as soon as possible after the collection. The analyte remained stable in processed samples in an autosampler (at 10°C) for up to 18 h. The method was successfully applied for the quantification of five authentic samples collected from volunteers attending parties and electronic music festivals. Psilocin concentrations ranged from 0.08 to 36.4 ng/mL. This is the first work to report psilocin concentrations in authentic oral fluid samples.