Environmentally friendly screen-printed electrodes for the selective detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B) in forensic analysis.

Analytical methods : advancing methods and applications  – November 14, 2024

Source: PubMed

Summary

Repurposing discarded electronics for vital forensic work is now a reality. Researchers created an environmentally friendly sensor from recycled components to selectively detect the illicit drug 2C-B. This innovative device, requiring minimal sample, accurately identifies 2C-B in real-world samples. It offers a rapid, portable, and sensitive screening tool for forensic analysis, proving highly effective even amidst other substances.

Abstract

In response to the growing need for sustainable analytical methods, this study explores the repurposing of screen-printed electrodes (SPEs) that would otherwise be discarded. This involves recoating the working electrode surface with a graphite (Gr) and chitosan (CTS) dispersion, creating a reusable SPE (SPE-Gr/CTS). Demonstrating its utility, SPE-Gr/CTS was employed for the detection of 4-bromo-2,5-dimethoxyphenethylamine (2C-B), a phenylethylamine commonly used for recreational proposes. Identifying 2C-B in fluid oral and seized samples is of great interest for forensic and toxicological applications. The 2C-B detection using SPE-Gr/CTS was optimized in Britton-Robinson buffer solution (0.1 mol L-1) at pH 2.0, employing square-wave adsorptive stripping voltammetry. The electrochemical behavior of 2C-B on SPE-Gr/CTS exhibited one irreversible oxidation and a reversible redox process. The proposed method presented a dynamic linear range for 2C-B determination (0.05 to 7.5 μmol L-1) with a low LOD (0.015 μmol L-1). Moreover, the stability of 2C-B electrochemical responses on SPE-Gr/CTS was confirmed using the same or different electrodes (N = 3), with a relative standard deviation of less than 5.0%. Interference studies with seventeen other illicit drugs and adulterants demonstrated that the proposed method is selective for 2C-B detection even in the presence of these substances. Real seized and oral fluid samples containing 2C-B were analyzed using this method, and the results were confirmed by LC-MS. The proposed device demonstrates to be an environmentally friendly and selective sensor for 2C-B detection in forensic analysis, offering a rapid and straightforward screening method for seized and biological samples. In addition, a portable and sensitive determination of 2C-B in forensic samples is presented with minimal sample consumption (50 μL).

Comments

No comments yet.

Log in to comment