Skip to content

The Development and Application of a Gas Chromatography-Mass Spectrometric (GC-MS) Assay to Determine the Presence of 2-Oxo-3-Hydroxy-LSD in Urine

B.t. Burnley, Stephen A. George

Journal of Analytical Toxicology May 1, 2003 DOI: 10.1093/jat/27.4.249 via OpenAlex

Summary

AI-generated from the abstract

A gas chromatography-mass spectrometry method was developed to measure the 2-oxo-3-hydroxy metabolite of lysergic acid diethylamide in urine, with a detection limit of 0.5 ng/mL and quantitation limit of 1.0 ng/mL. The assay was linear from 0.5 to 50.0 ng/mL. Applied to 600 urine specimens from suspected LSD abusers in the West Midlands, U.K., only 25 screened positive by immunoassay, and 11 were confirmed by GC-MS. Concentrations in confirmed specimens ranged from 1.7 to 55.8 ng/mL. The method enables future audits of LSD abuse and helps distinguish drug misuse from organic disorders.

Study at a glance

Characteristics Pilot study Peer reviewed
Sample size 600
Population Suspected LSD abusers in the West Midlands, U.K.
Topics LSD
Keywords Urine Detection limit Gas chromatography–mass spectrometry Chemistry Metabolite
Citations 14
Key finding Only 11 of 600 suspected LSD abusers were confirmed by GC-MS to contain OH-LSD, with concentrations ranging from 1.7 to 55.8 ng/mL.

Abstract

An accurate and reproducible gas chromatography-mass spectrometry (GC-MS) analytical method was developed to enable the Laboratory to determine the presence and concentration of the 2-oxo-3-hydroxy metabolite of lysergic acid diethylamide (OH-LSD) in urine. The limit of detection was 0.5 ng/mL, with a limit of quantitation established as 1.0 ng/mL. The assay was reproducible and linear over the concentration range 0.5-50.0 ng/mL, with a typical correlation coefficient (r2) of 0.997. This method was subsequently applied to the analysis of specimens submitted for routine drugs of abuse screening as part of an audit into the prevalence of LSD abuse in the West Midlands, U.K. This initial pilot study was performed using urine specimens obtained from 600 suspected LSD abusers. Following immunoassay screening, only 25 (6 female and 19 male subjects) were found to be LSD positive, but only 11 were confirmed as containing OH-LSD by GC-MS. The concentrations determined in these specimens ranged from 1.7 to 55.8 ng/mL (mean 11.0, median 5.4). This rapid and sensitive technique should enable the Laboratory to perform future audits of LSD abuse throughout the West Midlands and facilitate differential diagnoses to be made between drug misuse and underlying organic disorders.